麵對(duì)全(quán)自動超聲波清洗機這(zhè)三種故障怎麽處理?

作者:admin來源:http://www.ahfanglei.com/時間:2023-02-28

全自動超聲波清洗機將功率(lǜ)超聲頻源的聲能轉(zhuǎn)換(huàn)成機械振動,破(pò)壞汙物與清(qīng)洗件表麵的吸附,引起汙(wū)物層的(de)疲勞破壞而被駁離(lí),氣體型(xíng)氣(qì)泡(pào)的振(zhèn)動對固體表麵進行擦洗。那麽麵對全自動超聲波清洗機這三種故障怎麽處理?
The full-automatic ultrasonic cleaning machine converts the sound energy of the power ultrasonic frequency source into mechanical vibration, destroys the adsorption between the dirt and the surface of the cleaning part, causes the fatigue damage of the dirt layer and is removed, and the vibration of gas-type bubbles scrubs the solid surface. So how to deal with these three kinds of faults of automatic ultrasonic cleaning machine?
散熱風扇(shàn)能轉動,但無超聲波(bō)輸出
The cooling fan can rotate, but there is no ultrasonic output
可能是因為功率管損壞或保險絲熔斷,主板上的功率(lǜ)管(guǎn)會因為機器的長時間(jiān)使用,導致功率管出(chū)現短路(lù)情況。
It may be because the power tube is damaged or the fuse is blown. The power tube on the main board will be short-circuited due to the long time use of the machine.
功率管在主板上連接時,用萬用表測(cè)量(liàng)功率管兩側管(guǎn)腳(jiǎo)的阻值(zhí)。
When the power tube is connected on the main board, use a multimeter to measure the resistance of the pins on both sides of the power tube.
開(kāi)啟(qǐ)電源就(jiù)跳閘
Trip when the power is turned on
需要檢查(chá)發生器電源線有(yǒu)無短路,發生器(qì)整流橋是否有問題,可使用萬(wàn)用表測量發生器整流橋四個腳有沒短路,如果短路了,需要更換整(zhěng)流橋。
It is necessary to check whether the generator power line has a short circuit and whether the generator rectifier bridge has a problem. Use a multimeter to measure whether the four pins of the generator rectifier bridge have a short circuit. If there is a short circuit, replace the rectifier bridge.
全自動超聲波清洗機
清(qīng)洗效果不理想
The cleaning effect is not ideal
造成(chéng)這個問題有可能是因(yīn)為超聲波(bō)頻率協調沒有調節(jiē)好(hǎo)、清洗槽內的清洗液液位(wèi)放置不當或液體溫度過高、使用的清洗(xǐ)液不符合規格,這些(xiē)需要根據設備及被(bèi)清洗物品的材質大(dà)小(xiǎo)所調節。
This problem may be caused by improper adjustment of the ultrasonic frequency coordination, improper placement of the cleaning fluid level in the cleaning tank or high liquid temperature, and the use of cleaning fluid that does not meet the specifications. These need to be adjusted according to the material size of the equipment and the cleaned items.
為(wéi)了不影響(xiǎng)設備的正常使用,一(yī)旦發現問題需及時進行維修處理,不(bú)可帶“病”工作,以免造成更大的損傷。您有需求就來91污網站http://www.ahfanglei.com進行(háng)谘詢了解吧!
In order not to affect the normal use of the equipment, once problems are found, they need to be repaired and handled in time. Do not work with "disease" to avoid causing greater damage. Come to our website if you need http://www.ahfanglei.com Consult and understand!